Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add filters








Language
Year range
1.
Chinese Journal of Ultrasonography ; (12): 431-433, 2018.
Article in Chinese | WPRIM | ID: wpr-707694

ABSTRACT

Objective To analyze the ultrasonic and clinical features of fetal gastric duplication. Methods Ultrasonographic apperance of 12 fetal stomach duplication cases were reviewed and followed up. Results The age of 12 fetal gestational duplication cases ranged from 19 weeks to 36 weeks. All cases were cystic-type,and 11 cases of gastric duplication were diagnosed by antenatal ultrasonography. Eleven cases were normal labored,2 patients were cured after surgical management. One case was misdiagnosed to be bile duct cyst, and was induced in 1 week after diagnosis because of simultaneous combination of hydrocephalus in bilateral ventricle. Stomach duplication prenatal sonographic findings were cysts near the stomach with thickened wall in local enlarged images. The cystic wall included 3 layers of strong-weak-strong hierarchical structure as normal stomach wall. Conclusions Fetal stomach duplication has characteristic ultrasound features,and can be definitively diagnosed prenatally. Early diagnosis is of great importance for prenatal consultation and timely treatment after birth.

2.
Chinese Journal of Endocrine Surgery ; (6): 333-334, 2011.
Article in Chinese | WPRIM | ID: wpr-622365

ABSTRACT

Objective To study the relation between thyroid nodule and urine iodine and to provide a scientific basis for etiological research of thyroid nodule.Methods 178 cases of thyroid nodule were detected urine iodine concentration (μg/L) by As ( Ⅱ ) 2Ce4 + catalytic spectrophotometry.160 normal people were set as control group.Data of the 2 groups and the correlative clinical information were analyzed.Results The median urine iodine concentration was 116.2 μg/L for the 178 cases of thyroid nodule,217.2 μg/L for the control group.Among the 178 cases,the median urine iodine concentration was 125.6 μg/L for the 92 cases with nodule size > 10 mm and 136.4 μg/L for the 86 cases with nodule size < 10 mm.The difference of urine iodine had no statistical significance between the thyroid nodule group and the control group.There was no correlation between urine iodine and the size of thyroid nodule as well as sex.Conclusions No correlation is found between urine iodine and thyroid nodule.Patients with thyroid nodule,no matter male or female,don't have to restrict iodine intake excessively.

3.
Chinese Journal of Endocrine Surgery ; (6): 112-113, 2011.
Article in Chinese | WPRIM | ID: wpr-622186

ABSTRACT

Objective To investigate the prevalence of thyroid nodule(TN)in healthy adults of Yantaishan Hospital.Methods High frequency probe and color Doppler uhrasonography were applied to TN screening in 1125 employees of Yantaishah Hospital.Results In the 1125 adults of Yantaishan Hospital.418 were found to have TN.accounting for 37.2%of all employees.TN incidence increased with age.Thyroid nodule detection rate in female was higher than that in male(40.2%in females and 23.6%in male).The magnitude of the minimum nodule was 2 mm×1 mm in size.13 cases of TN were proved to be thyroid carcinoma.consisting 1.16%of all adults examined.Conclusion The incidence of TN and thyroid carcinoma in Yantaishan Hospital is highcr than that reported in other areas,indicating the necessity of carrying out TN screening among the healthy population.

4.
Chinese Journal of Endocrine Surgery ; (6): 250-252, 2011.
Article in Chinese | WPRIM | ID: wpr-622114

ABSTRACT

ObjectiveTo study the effects of dexamethasone local injection as an adjunctive therapy for Hashimoto thyroiditis (HT). Methods60 HT cases were equally divided into 2 groups at random. The patients in the control group were given euthyrpx while the patients in the treated group were injected dexamethasone in addition to the medicine used in the control group. The thyroid characters such as thickness, lymphocytic infiltration and changes of thyroid follicle were observed. The patients were followed up before treatment and 4, 12, 24weeks and 1 year after treatment. ResultsIn the treatment group, all thyroid glands turned significantly softer,and the mass became smaller compared with that in the control group. The pathology of thyroids indicated that lymphocytic infiltration decreased, local immune reaction was ameliorated, and no obvious hormone side effects were observed. ConclusionLocal use of dexamethasone can modify the structure and function of thyroid.

5.
Chinese Journal of Ultrasonography ; (12): 703-706, 2011.
Article in Chinese | WPRIM | ID: wpr-421384

ABSTRACT

Objective To explore the ultrasound appearance of primary synovial osteochondromatosis (PSO) of the knee. Methods Thirty-eight cases with PSO were confirmed by pathology, their ultrasound features were analyzed retrospective. Results Two hundred and sixty calcify nodules showed medium echo and several motting or bolus strong echo. Two hundred and eighty-nine ossify nodules showed slightly strong echo or strong echo,or only showed arc strong echo with rear sound shadow near nodules. Twenty-six mixed type nodules showed promiscuity moderately strong echo or with rear sound shadow. Forty introsynovium cartilage lesser nodules showed synovium thickening and similar round low echo nodules,30 sursynovium lesser nodules showed high echo, with a pedicel connected to synovium, can shift deform or sway because of the pressure from transducer, often concomitance other type nodules. Ten cartilage greater nodules showed similar round or lobulated low or medium echo tuberculum. Conclusions Ultrasound can show multiple nodules of PSO of the knee, especially noncalcific nonage smaller cartilage nodules. It is helpful for clinicians to decide more reasonable operation strategy.

6.
Chinese Journal of Ultrasonography ; (12): 47-50, 2010.
Article in Chinese | WPRIM | ID: wpr-391346

ABSTRACT

Objective To investigate the braking time in diagnosis of lipohemarthrosis by ultrasound. Methods Experiment group:After 20 tubes containing fresh blood and pig marrow were uniformly mixed, they were instantly continuously detected by high-frequency linear array transducer in fixed-area at short-interval.Clinical group: Ten walking patients with lipohemarthrosis were examined with continuous detection by ultrasound,CT and MR before operation.Results Experiment group: Cloudy echo and slowly floating up of lipoids were detected at the beginning.After 2.7 to 3.7 minutes (average 3.17 minutes), the liquid was divided into two layers with vague boundary.After 5.3 to 8.0 minutes (average 6.75 minutes) ,the liquid was divided into 3 layers with thickening serum laye.Clinical group: Ultrasound findings: Cloudy medium echo was detected at first.After 2.0 to 4.0 minutes (average 3.08 minutes),the liquid was divided into two layers.After 4.4 to 10.0 minutes (average 6.92 minutes) , the liquid was divided into 3 layers with thickening serum layers.Three knees showed fracture line and 2 knees with occult fracture were diagnosed as lipohemarthrosis.CT and MR findings: Ten knees showed fracture line in CT examination,of which 7 knees showed double liquid-liquid layer and 3 knees showed single liquid-liquid layer in the suprapatellar bursa.Ten knees showed fracture line in MR examination,6 knees showed double liquid-liquid layer and 4 knees showed single liquid-liquid layer in the suprapatellar bursa. Conclusions The best braking time in diagnosing lipohemarthrosis by ultrasound can be shorten to 10 minutes and the necessary braking time is 2 to 4 minutes.

7.
Chinese Journal of Medical Imaging Technology ; (12): 1827-1829, 2009.
Article in Chinese | WPRIM | ID: wpr-471746

ABSTRACT

Objective To explore the correlation between ultrasonographic findings and relevant technical factors in traumatic lipohemarthrosis. Methods Fifty-two patients with traumatic lipohemarthrosis underwent ultrasonic examination in supine position (26 in unbent, 16 in external rotary position, 10 in unbent and 45° rotation) before operation, and 22 of them underwent dynamic examination. Findings of ultrasography were compared with manifestations of MRI and CT regarded as gold standard.Results Fifty-two patients with traumatic lipohemarthrosis were diagnosed correctly. The best effect of ultrasonic examination of lipohemarthrosis was observed on suprapatellar bursa. Superior border of patella were showed well in supine straight position, then turned to the level of patella, and the structure below patella were showed badly. The best posture was in supine genuflex position with 45° rotation when the joint effusion presented, by which thicker layer liquids could be displayed than in straight position. Three layer liquids could not be displayed synchronously in mild external rotary rest position of lower extremity, and the combination of findings at internal and external side were favorable to the diagnosis. Liquids bed changed from one layer to two layers and then to three layers, from fuzzy to clear gradually in dynamic examination.Conclusion Ultrasonic manifestations of traumatic lipohemarthrosis are closely correlated to the position, posture and arresting time during examination.

SELECTION OF CITATIONS
SEARCH DETAIL